Installation Guide
Title Description Type Download
IG-0026 : FLB 3204 - 4G (Europe) Extension Card

This document describes the hardware of the FLB 3204 - LTE (Europe) extension card which belongs to the eWON Flexy family.

PDF
IG-0025 : FLB 3203 - 4G (Verizon) Extension Card

This document describes the hardware of the FLB 3203 - LTE (Verizon) extension card which belongs to the eWON Flexy family.

PDF
IG-0027 : FLB 3205 - 4G (NA) Extension Card

This document describes the hardware of the FLB 3205 - LTE (NA) extension card which belongs to the eWON Flexy family.

PDF
IG-0029-00 : FLC 3701 - MPI Extension Card

This document describes the hardware of the FLC 3701 - MPI extension card which is operational with the eWON Flexy 205 only.

PDF
IG-0028-00: Installation Guide for Flexy 205

This document describes the hardware of the Flexy 205 and explains how to get started with the embedded web site. It also describes the basic software features needed to install the equipment.

PDF
IG-016-0-EN (eWON Flexy - 2 Serial Ports Extension Card)

This Installation Guide explains how to install the eWON Flexy 2 Serial Ports Extension Card FLA 3301

PDF
IG-017-0-EN (eWON Flexy - Single Ethernet Extension Card)

This installation guide explains how to install the eWON Flexy Single Ethernet Extension Card FLX 3101

PDF
IG-019-0-EN (eWON Flexy - 3G GSM Extension Card)

This installation guide explains how to install the eWON Flexy 3G GSM Extension Card FLB 3202

PDF
IG-020-0-EN (eWON Flexy - Wifi Extension Card)

This installation guide explains how to install the eWON Flexy Wifi Extension Card FLB 3271

PDF
IG-021-0-EN (0eWON Flexy - PSTN Extension Card)

This installation guide explains how to install the eWON Flexy PSTN Extension Card FLA 3501.

PDF
IG-018-1-EN (eWON Flexy - 8DI-4AI-2DO Extension Card)

This installation guide explains how to install the eWON Flexy 8DI-4AI-2DO Extension Card FLX 3402.
This Extension Card replaces the old 8DI-4AI-2DO Extension Card FLX 3401 since July 2016

PDF
IG-024-0-EN (eWON Flexy - USB Extension Card)

This installation guide explains the USB Extension Card FLB 3601, its characteristic and how to install it in the eWON Flexy Base Unit.

PDF
Datasheet
Title Description Type Download
Flexy 205

This document targeting the Flexy 205 lists commercial & technical information: features, base unit, modules, extension cards, components, ...

PDF
User Manual
Title Description Type Download
UM-0002-00: Flexy Family

This guide presents the features of the eWON Flexy and explains briefly the steps to take to get a functional eWON device.

PDF
Application User Guide
Title Description Type Download
AUG-036 Remote Access for Omron PLCs

This guide explains in a few steps how to configure your eWON, your Talk2M account and your PLC software to access your Omron PLCs for remote diagnosis and programming.

PDF
AUG-066: Connect 2 sites together using VPN through mobile network

Learn how to connect 2 remote eWON devices securely over the Internet using a mobile connection (through a VPN connection).

PDF
AUG-0071-0: Polling Data from a BACNET IP Device

The objective of this document is to explain how the eWON can poll data variables out of one or more BACNET/IP devices using the BACNET IO Server embedded in the eWON with firmware version < 12.2.

PDF
AUG-037 Remote Access for Siemens S7-300&400 PLCs

This guide explains in a few steps how to configure your eWON, your Talk2M account and your PLC software to access your Siemens S7-300, S7-400 PLCs and their VIPA equivalents S300 - SPEED7 for remote diagnosis and programming.

PDF
AUG-069 : EUM Card - Extend eWON User directory memory

Learn how to extend the embedded filesystem (meaning the /usr directory) of the eWON with an EUM Card (formatted as ext3 filesystem) plugged inside.

PDF
AUG-038 Remote Access for Schneider Modicon Micro & Premium PLCs

This guide explains in a few steps how to configure your eWON, your Talk2M account and your PLC software to access your Schneider Electric Modicon Micro & Premium Series PLCs for remote diagnosis and programming.

PDF
AUG-0071-1: Polling Data from a BACNET IP Device

The objective of this document is to explain how the eWON can poll data variables out of one or more BACNET/IP devices using the BACNET IO Server embedded in the eWON with firmware version >= 12.2.

PDF
AUG-042 Access Schneider PLCs through an existing Talk2M connection

This short guide explains how to access an Schneider Electric PLC remotely through Talk2M and a pre-configured eWON. Applications include remote servicing of PLC-controlled equipment.

PDF
AUG-070 : PLC discovery through Talk2M

Learn how to configure the eWON and the eCatcher software in order to discover the PLC available on a distant network that you are connected to through the Talk2M connection.

PDF
AUG-043 Remote Access for Mitsubishi PLCs

This guide explains in a few steps how to configure your eWON, your Talk2M account and your PLC software to access your Mitsubishi FXand Q-Series PLCs for remote diagnosis and programming.

PDF
AUG-039 Access Allen-Bradley PLCs through an existing Talk2M connection

This short guide explains how to access an Allen-Bradley® PLC remotely through Talk2M and a pre-configured eWON. Applications include remote servicing of PLC-controlled equipment.

PDF
AUG-044 Access Mitsubishi PLCs through an existing Talk2M connection

This short guide explains how to access an Mistubishi PLC remotely through Talk2M and a pre-configured eWON. Applications include remote servicing of PLC-controlled equipment.

PDF
AUG-040 Access Siemens PLCs through an existing Talk2M connection

This short guide explains how to access an Siemens PLC remotely through Talk2M and a pre-configured eWON. Applications include remote servicing of PLC-controlled equipment.

PDF
AUG-047 Remote Access for Siemens S7-300&400 PLCs through TIA

This guide explains in a few steps how to configure your eWON, your Talk2M account and your PLC software to access your Siemens S7-300, S7-400 PLCs through TIA for remote diagnosis and programming.

PDF
AUG-032 eVCOM - Getting Started

eVCOM is the Virtual COM software for eWON. With eWON and eVCOM software, you can achieve long distance access to a serial device by creating, on your computer, a virtual COM port linked to an eWON placed beside your serial device.

PDF
AUG-041 Access OMRON PLCs through an existing Talk2M connection

This short guide explains how to access an Omron PLC remotely through Talk2M and a pre-configured eWON. Applications include remote servicing of PLC-controlled equipment.

PDF
AUG-0045-1: Polling Data Registers from Allen-Bradley PLCs

This short guide explains how to poll data registers from AllenBradley® PLCs with firmware version >= 12.2.

PDF
AUG-054 Remote Access for Schneider M258 PLCs

This guide explains in a few steps how to configure your eWON COSY, your Talk2M account and your PLC software to access your Schneider M258 PLCs for remote diagnosis and programming.

PDF
AUG-0048-1: Polling Data Registers from Siemens PLCs

This guide explains how to poll data registers from Siemens PLC Series - S7-300, S7-400 & S7-1200 with firmware version >= 12.2. 

PDF
AUG-0049-1: Polling Data Registers from Siemens S7-200 PLCs

This guide explains how to poll data registers from Siemens S7-200 PLC Series with firmware version >= 12.2.

PDF
AUG-0073-00: Getting started with MQTT

This document describes how to set up your Flexy to be an MQTT Client.

PDF
AUG-015 Linking 2 Sites Together Using VPN

The purpose of this document is to explain how to connect 2 remote equipments over the Internet using the second Ethernet interface of 2 eWONs (though a VPN connection).

PDF
AUG-0074: OPC UA Client

How to retrieve tags in OPC UA from a third-party device to the eWON Flexy.

PDF
AUG-062 : eWON configured by SD Card

Configure your eWON with an SD Card and perform actions such as a firmware upgrade / downgrade or even a recovery, restore a backup, integrate it in your Talk2M account...

PDF
AUG-061 : eWON Geolocation

Discover how to set up the geolocation feature of your eWONs based on its WAN connectivity and retrieve the information in eCatcher, the Talk2M companion tool.

PDF
AUG-0064: OPC UA Server

How to publish Tags in OPC UA, a SCADA protocol used by the eWON Flexy.

PDF
AUG-0045-0: Polling Data Registers from Allen-Bradley PLCs

This short guide explains how to poll data registers from AllenBradley® PLCs with firmware version < 12.2.

PDF
AUG-0048-0: Polling Data Registers from Siemens PLCs

This guide explains how to poll data registers from Siemens PLC Series - S7-300, S7-400 & S7-1200 with firmware version < 12.2. 

PDF
AUG-035 Remote Access for Allen Bradley PLCs

This guide explains in a few steps how to configure your eWON, your Talk2M account and your PLC software to access your AllenBradley® PLCs for remote diagnosis and programming.

PDF
AUG-0049-0: Polling Data Registers from Siemens S7-200 PLCs

This guide explains how to poll data registers from Siemens S7-200 PLC Series with firmware version < 12.2.

PDF
Reference guide
Title Description Type Download
RG-0008-00 : Flexy Family

This document describes all configuration parameters of the Flexy 205.

PDF
RG-0009-00 : Export Block Descriptor

Learn more about the EBD which are used to export block descriptor data from the eWON devices.

PDF
RG-0007-00 : IO Servers

Learn more about IO serves and the concept of any variable from any data source must have a common representation for all IO Servers in order to define common interface in the eWON.

PDF
IO Server
Title Description Type Download
IOServer_Modbus.pdf PDF
IOServer_S5.pdf PDF
IOServer_S7_200.pdf PDF
IOServer_S7_300_400.pdf PDF
IOServer_SNMP.pdf PDF
IOServer_Unitelway.pdf PDF
IOServer_ABLogix.pdf PDF
IOServer_FINS.pdf PDF
IOServer_DF1.pdf PDF
IOServer_Hitachi.pdf PDF
IOServer_MELSEC.pdf PDF
IOServer_MitsuFX.pdf PDF
Official Documents
Title Description Type Download
Type Examination Certificate for FLB 3271

Declaration of compliance with the essential requirements in accordance with Article 3 of Directive 2014/53/EU for the Wi-Fi extension card FLB 3271.

PDF
Flexy - EU Declaration of conformity PDF
UL Certificate Of Compliance (CoC) E350576-20160219 PDF
UL Certificate Of Compliance (COC) E350576-20180514 PDF
eWON Declaration of origin PDF
Flexy - CB certificate # DK-53957-A1-UL

IEC System for mutual recognition of test certificates for electrical equipment (IECEE) CD scheme.

PDF
UL Certificate Of Compliance (CoC) E350576-20190529 PDF
EU Type Examination Certificate

Proof of conformity for Flexy 205, FLB 3204 and FLC 3701 in regards of Safety (RED, Article 3.1a), Health (RED, Article 3.1a), EMC (RED, Article 3.1b) and Radio Specturm (RED, Article 3.2).

PDF
Flexy - CB certificate # DK-84039-UL

IEC System for mutual recognition of test certificates for electrical equipment (IECEE) CD scheme.

PDF
3D Drawings
Title Description Type Download
Flexy 205 - DWG version

This is the DWG version of the 3D drawing for the Flexy 205 with the power supply connector.

ZIP
Flexy 205 - PDF

This is the PDF version of the 3D black & white drawings for the Flexy 205 with the power supply connector.

PDF
Flexy 205 - PDF

This is the PDF version of the 3D drawings with measure for the Flexy 205.

PDF
Flexy 205 - STEP

This is the STEP version of the 3D drawings for the Flexy 205 without the power supply connector.

ZIP
Flexy 205 - STEP

This is the STEP version of the 3D drawings for the Flexy 205 with the power supply connector.

ZIP